CEN/TS 1090-201 — Reuse of Structural Steel
Certification of an organisation's process for reusing structural steel — identifying and deconstructing components from an existing structure, assessing whether they can be reused, and establishing and declaring their properties for execution to EN 1090-2 — against CEN/TS 1090-201:2024 (published in the UK as PD CEN/TS 1090-201:2024 and in Italy as UNI CEN/TS 1090-201:2025). The certificate is a Certificate of Conformity, issued By CAS under its own authority, outside the EGAC accredited scope, with no EGAC or IAF mark. It is not CE marking.
Standard
CEN/TS 1090-201:2024
Service type
By CAS
Issued under
CAS — own authority
What it is
CEN/TS 1090-201:2024, Execution of steel structures and aluminium structures — Reuse of structural steel, is a CEN Technical Specification prepared by CEN/TC 135, Execution of steel structures and aluminium structures, the committee that also prepares the EN 1090 series. It gives complementary provisions to EN 1090-2 for using reclaimed structural components — components salvaged from a donor structure to be used again in a recipient structure — in the execution of steel structures in execution classes EXC1, EXC2 and EXC3. It applies to structures designed to EN 1993-1-1 for quasi-static loading and not subject to fatigue loading; national standards bodies may add non-contradictory requirements, for example on seismic loading. It asks for an identification system, set up before deconstruction, that traces reclaimed components to their provenance, location and function, and for deconstruction, handling and storage that limit damage. Components then go through a reusability assessment, based on the available records of the donor structure and a visual condition evaluation, and a quality assessment that declares, for plates, hot rolled profiles and hot finished or cold formed hollow sections in carbon steel, the properties EN 1090-2 requires of constituent products: yield and tensile strength, elongation, tolerances on dimensions and shape, heat treatment delivery condition for hollow sections, and weldability. These properties are established by measurement and by non-destructive and destructive testing, to an extent that depends on the information available and on the outcome of the reusability assessment, and the results are kept in an inspection and test record. The quality assessment requirements also apply to fabricated components, but the recommendations for assessing connections, in particular welds, are informative only. It does not apply to cold-formed sections and sheeting covered by EN 1090-4 or to mechanical fasteners. CEN approved it on 5 August 2024 for provisional application, with a validity limited initially to three years; after two years CEN members are asked whether it can be converted into a European Standard. A Technical Specification is not a European Standard and is not harmonised: on its own it gives no route to CE marking.
Who needs it
Steel fabricators, deconstruction and demolition contractors, stockholders of reclaimed steel, and the clients and contractors of circular construction projects who reclaim, assess, supply or fabricate structural steel for reuse and want independent evidence that they follow CEN/TS 1090-201.
Audit process
CAS audits the organisation's process for reusing structural steel, within the scope stated on the certificate, against CEN/TS 1090-201:2024 as a complement to EN 1090-2 — the identification system and deconstruction, the reusability assessment of reclaimed components, the quality assessment and testing that establish their declared properties, and the inspection and test record that documents them. Certification follows an initial audit, annual surveillance audits and recertification every three years. Because CEN/TS 1090-201 is a provisional Technical Specification, the certificate follows any decision CEN takes on it: if CEN withdraws it or replaces it with a European Standard (EN), the certification moves to the replacing document at the next audit, or the certificate is withdrawn; the certificate says so. The certificate is a Certificate of Conformity issued By CAS, outside CAS's EGAC accreditation, and can be verified on CAS CertSearch. It covers the organisation's process: it does not certify a particular structure or batch of steel, it does not declare the properties of any reclaimed component, and it is not EN 1090-1 factory production control certification.
Frequently asked questions
Common questions
Is CEN/TS 1090-201 certification by CAS accredited?
No. CAS issues CEN/TS 1090-201 certificates By CAS, under its own authority and outside its EGAC accreditation, which covers ISO 9001, 14001, 45001, 22000, 50001 and 22301 only. The certificate carries the CAS mark, not the EGAC or IAF marks, and can be verified on CAS CertSearch.
Is this CE marking under EN 1090-1?
No. CE marking of structural steel components under EN 1090-1 needs factory production control certification by a notified body under the Construction Products Regulation. CEN/TS 1090-201 is a Technical Specification, not a harmonised standard, and a certificate By CAS does not support CE marking.
PD CEN/TS 1090-201, UNI CEN/TS 1090-201 or CEN/TS 1090-201?
The same document. CEN/TS 1090-201:2024 is the CEN Technical Specification; national standards bodies publish it under their own prefix — BSI as PD CEN/TS 1090-201:2024 and UNI as UNI CEN/TS 1090-201:2025. The certificate names CEN/TS 1090-201:2024.
Which steel and which structures does CEN/TS 1090-201 cover?
Reclaimed plates, hot rolled profiles and hot finished or cold formed hollow sections in carbon steel, reused in steel structures executed to EN 1090-2 in execution classes EXC1 to EXC3 and designed to EN 1993-1-1 for quasi-static loading, not subject to fatigue loading. It does not apply to cold-formed sections and sheeting covered by EN 1090-4 or to mechanical fasteners, and its recommendations for assessing connections and welds are informative only.
Does the certificate say that a reused steel member is fit for a new structure?
No. It attests that CAS audited the organisation's reuse process and found it conforming. Whether a given component suits a particular structure remains for the designer and the execution specification of that project to decide.
Ready to certify against CEN/TS 1090-201:2024?
Tell us about your organisation and scope — we’ll come back with a costed proposal, usually within two business days. No obligation.