Key takeaways
- 1EN ISO 9606-1:2017 — Steels.
- 2EN ISO 9606-2:2004 — Aluminium and aluminium alloys.
- 3EN ISO 9606-3:1999 — Copper and copper alloys.
- 4EN ISO 9606-4:1999 — Nickel and nickel alloys.
Short answer: a welder qualification test certificate — in Italy, the “patentino del saldatore” — is issued to the EN ISO 9606 series. It covers one test piece and the range of qualification the standard gives for it; under EN ISO 9606-1 the welder's work is confirmed every 6 months, and the qualification is revalidated by one of the three methods of clause 9.3.
What the qualification test is
The EN ISO 9606 series sets the qualification test a welder takes to show the skill to make sound fusion welds in a given group of materials. The welder welds a test piece to a welding procedure specification (WPS or pWPS); the piece is examined and tested; and the variables of the test — welding process, product form (plate or pipe), type of weld, material group, filler, thickness, outside pipe diameter, welding position and weld details — define the range of qualification printed on the certificate. A welder qualified on one test piece is qualified only within that range.
One part of the series for each material
- EN ISO 9606-1:2017 — Steels.
- EN ISO 9606-2:2004 — Aluminium and aluminium alloys.
- EN ISO 9606-3:1999 — Copper and copper alloys.
- EN ISO 9606-4:1999 — Nickel and nickel alloys.
- EN ISO 9606-5:2000 — Titanium and titanium alloys, zirconium and zirconium alloys.
One test, one range of qualification
Each certificate covers one test piece, and its range of qualification — positions, thicknesses, diameters, material groups, fillers and weld details — is the range the standard's tables give for that piece. Work outside the range needs another test and another certificate. The welder welds the test piece in the presence of an examiner approved by CAS. The examiner submits the test record with the reports of the visual testing and of the further tests the standard requires for that test piece — for example radiographic testing, bend tests, fracture tests or macroscopic examination — which may be carried out by a testing laboratory approved by CAS. CAS reviews the record and the reports, works out the range of qualification from the standard's own tables (the examiner may narrow it, never widen it) and issues one certificate for each test piece.
How long it lasts, and how it is revalidated
Under EN ISO 9606-1 the qualification begins on the date the test piece was welded, and the method of revalidation is chosen at issue and printed on the certificate (clause 9.3):
- a) a new test every 3 years;
- b) every 2 years, two production welds made in the last 6 months of the period are tested by radiographic, ultrasonic or destructive testing;
- c) validity for as long as it is confirmed, while the welder works for the manufacturer they qualified for, whose quality programme has been verified to ISO 3834-2 or ISO 3834-3 and who documents that the welder has produced welds of acceptable quality to the application standards.
- EN ISO 9606-2 to -5: the qualification is valid for 2 years and may be prolonged by the examiner for further 2-year periods on the evidence the standard lists.
Under every part, the welder's work within the range of qualification is confirmed every 6 months; a qualification whose 6-month confirmation is missing lapses.
When an accredited or a notified body is required
CAS issues welder qualification certificates By CAS, under its own authority. They are outside CAS's EGAC accreditation, which covers ISO 9001, 14001, 45001, 22000, 50001 and 22301 management-system certification only, and they carry no EGAC or IAF mark. Where a regulation, code or contract requires the qualification to be issued by an accredited body or a notified body, a By CAS certificate does not meet that requirement. For pressure equipment of PED categories II, III and IV, the Pressure Equipment Directive requires the qualification to be approved by a competent third party — a notified body or a recognised third-party organisation — and for simple pressure vessels by a notified body; a By CAS certificate meets neither requirement, and validity method c) is not permitted for PED categories II to IV. In Italy a By CAS certificate does not replace one issued by a body accredited by Accredia (or another EA MLA signatory), or by a notified body, where a regulation, a code or a contract requires it.
What the certificate shows, and how to check it
It shows the welder's identification, the standard and its edition, the test piece and the range of qualification for each variable, the tests performed and their results, the date of welding, the validity and its 6-month confirmations, and the examiner who witnessed the test, in English and Italian. Anyone can check a certificate on CAS CertSearch by its number, which shows the holder's name, the scope and the validity only — no date of birth, identity number or photograph. The service is described on our welder qualification page; welding operators and weld setters are qualified to EN ISO 14732, brazers to EN ISO 13585, and a manufacturer's welding quality requirements are certified to EN ISO 3834.
CAS Conformity Assessment Services — EGAC-accredited certification body, CAB No. 012418. EGAC accreditation covers ISO 9001, 14001, 45001, 22000, 50001 and 22301 only, and IAF MLA recognition covers the same list except ISO 22301. Welder qualification certificates are issued By CAS, outside both.
Read next