Key takeaways
- 1internal audits and management review;
- 2the actions taken on nonconformities identified at the previous audit;
- 3complaints handling;
- 4the effectiveness of the system in achieving the client's objectives and its intended results;
An accredited management system certificate runs on a three-year cycle. ISO/IEC 17021-1:2015 §9.1.3.2 sets its shape: a two-stage initial audit, surveillance audits in the first and second years following the certification decision, and a recertification audit in the third year, before certification expires. The first cycle begins with the certification decision, not with the audit. This is the calendar, year by year.
Before the cycle: stage 1, stage 2 and the decision
The initial certification audit is conducted in two stages (§9.3.1.1). The interval between them takes account of the time the client needs to resolve the areas of concern found at stage 1 (§9.3.1.2.4). For ISO 22000, ISO 22003-1:2022 adds a limit: the interval shall not be longer than six months, and stage 1 is repeated if a longer interval is needed (§9.3.6).
After stage 2, the certification decision is taken by people other than those who carried out the audits (§9.5.1.1). That decision opens the first cycle (§9.1.3.2). The effective date on the certificate cannot be earlier than the decision (§8.2.2 b)), and the decision date is the one the first surveillance deadline is counted from.
The audit programme behind the calendar
The certification body develops an audit programme for the full cycle, and the programme for the cycle covers the complete management system requirements (§9.1.3.1). It can change during the cycle: the programme and any later adjustments consider the size of the client, the scope and complexity of its system, products and processes, the effectiveness the system has demonstrated, and the results of previous audits (§9.1.3.2).
A note to the same clause allows an industry-specific certification scheme to set a cycle of a different length. The calendar below is the three-year one in the clause.
Year one: the first surveillance audit
Surveillance audits are conducted at least once a calendar year, except in recertification years. The date of the first one after initial certification shall "not be more than 12 months from the certification decision date" (§9.1.3.3). The 12 months run from the decision, not from the last day of stage 2.
A surveillance audit is an on-site audit, but not necessarily a full system audit (§9.6.2.2). Each one covers:
- internal audits and management review;
- the actions taken on nonconformities identified at the previous audit;
- complaints handling;
- the effectiveness of the system in achieving the client's objectives and its intended results;
- progress of planned continual improvement activities;
- continuing operational control;
- any changes;
- use of marks and any other reference to certification.
For ISO 9001, ISO 14001 and ISO 45001, the time spent each year on surveillance during the first cycle is about one third of the initial audit time, and recertification is about two thirds of what an initial audit would need at the time of recertification (Global ACI TECH-3-004 (formerly IAF MD 5) §5 and §6). At each surveillance audit, the certification body also obtains updated client data, and it reviews the planned audit time for changes in the organization and the maturity of its system (§5).
Year two: the second surveillance audit
The second surveillance follows the same calendar-year rule and covers the same list. Where it looks can differ. Surveillance is developed so that representative areas and functions within the scope are monitored on a regular basis, taking account of changes to the client and its system (§9.6.2.1.1). A surveillance audit is not necessarily a full system audit (§9.6.2.2); it is the programme for the whole cycle that covers the complete management system requirements (§9.1.3.1).
For a multi-site organization audited by site sampling, the central function is audited at initial certification, at every recertification, and at least once a calendar year as part of surveillance (Global ACI TECH-3-001 (formerly IAF MD 1) §6.1.3.4).
Year three: recertification before expiry
The calendar-year surveillance rule does not apply in a recertification year (§9.1.3.3). The recertification audit is planned and conducted in due time for renewal before the certificate's expiry date (§9.6.3.1.1).
It includes a look back: the review of previous surveillance audit reports and of the system's performance over the most recent cycle (§9.6.3.1.2). Where there have been significant changes to the system, the organization or its context, a stage 1 may be needed (§9.6.3.1.3).
The on-site audit then addresses three things (§9.6.3.2.1):
- the effectiveness of the system in its entirety, in the light of internal and external changes, and its continued relevance to the scope;
- demonstrated commitment to maintain its effectiveness and improvement;
- its effectiveness in achieving the client's objectives and intended results.
For any major nonconformity, corrections and corrective actions are implemented and verified before certification expires (§9.6.3.2.2). The renewal decision rests on the results of the recertification audit, the review of the system over the period of certification, and complaints received from users of certification (§9.5.4). That decision opens the next cycle (§9.1.3.2).
The second cycle
Later cycles begin with the recertification decision and keep the rule of at least one surveillance each calendar year outside recertification years (§9.1.3.3). For ISO 9001 and ISO 14001, TECH-3-004 §7 allows a certification body to design an individualised surveillance and recertification programme for second and later cycles, with its accreditation body's approval. This does not apply to ISO 45001. Without such a programme, audit time should be calculated as in its clauses 5 and 6.
What this means for you
If you are newly certified: ask your certification body for the date of the certification decision. The first surveillance audit falls no more than 12 months after it.
If you are preparing for a surveillance audit: the items above are on every surveillance, including internal audits, management review and the actions on the previous audit's nonconformities.
If you are approaching year three: recertification reads the whole cycle, surveillance reports included, and is planned to finish before the expiry date.
If you are a buyer: between issue and expiry, certification is maintained through surveillance (§9.6.1 and §9.6.2). The certification body gives the status of a given certification on request (§8.1.2 b)); read it on its register.
This is generic information about the requirement, not advice on any particular management system.
CAS — An EGAC accredited MS certification body No. 012418. Accredited scope: ISO 9001, ISO 14001, ISO 45001, ISO 22000, ISO 50001 and ISO 22301. Certificates accredited for ISO 9001, 14001, 45001, 22000 and 50001 fall within EGAC's IAF MLA scope; ISO 22301 is accredited by EGAC and sits outside that scope.